-40%

YORK 3 TON 208-230V 3 PHASE LIGHT COMMERCIAL STYLE GAS PACKAGE UNIT.

$ 871.2

Availability: 100 in stock
  • Equipment Type: Gas Package unit
  • Country/Region of Manufacture: Unknown
  • Brand: YORK
  • MPN: Does Not Apply
  • Seer: 13
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Voltage: 208/230 V 3PHASE
  • Return shipping will be paid by: Buyer
  • Model: D6NZ036N07225NXA
  • Condition: New un-used Unit. May have some scratches or dent's as seen in the pictures. Age may vary please look at the pictures and the listing for additional information.
  • Type: Air Cooled Condenser
  • Capacity: 3 Ton
  • Item must be returned within: 30 Days
  • Suitable Location: Outdoor Only
  • Refrigerant: R-410a

    Description

    Wade's Heating, Cooling & Electrical
    "
    Whatever It Takes
    "
    eBay Shop
    Feedbacks
    Add to favorites
    About Us
    Contact
    Service and Support
    phone: (870) 307-0460
    Product description
    YORK
    D6NZ036N07225NXA
    3 TON - 208-230V 3 PHASE
    Light Commercial Grade Gas Package Unit
    This is a 2015 Model Standard efficiency 3 Ton 208/230v 3phase York Light Commercial Grade gas package unit.  This unit is new and never been installed.
    This unit does come with a 1 year all parts warranty (Not including Labor) from us here personally here at Wade's Heating, Cooling and electrical.
    This unit can be used both in a vertical or horizontal discharge application.  The features and benefits of this unit are listed below.
    Features and Benefits
    Standard Features
    • Operating Efficiency - DNZ model gas units provide a minimum AFUE of 80 and SEERS of 13.0. DNQ model gas units provide a minimum AFUE of 81 and 14 SEER /12 EERs. DNX model gas units provide a minimum AFUE of 81 and SEERS of 15.0 to 16.5. All efficiencies exceed legislated minimum levels.
    • On Site Flexibility - All model sizes share a common, compact design cabinet in a single footprint. The installer has the flexibility of setting one curb and placing the proper tonnage unit on that curb after the internal load has been determined. Field convertible duct connections from side shot to down shot  allows the installer to have greater flexibility with less inventory.
    • Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof, plus, the installer can fit this unit between the wheel wells of full size pick-up truck. All units are completely wired, charged with R-410A and tested prior to shipment. Unique test stations using a new state of the art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified via computers at assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. Equal size, side supply and return duct connections allows easy hook-up of ducts to match low crawl spaces without transition pieces.
    • Utility Connections Made Easy - Gas and electric utility knockouts are provided through the bottom as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed.
    • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory ready to be used for a side supply/side return application. If a bottom supply/bottom return application is  desired, you simply remove the two panels from the bottom of the unit and lace them in the side supply/side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum  field flexibility and minimum inventory.
    • Condensate Pan - A non-corrosive, long-lasting, watertight pan is positioned below the evaporator coil to collect and drain all condensate. Less collection of stagnate condensate will build-up. The condensate pan conforms to ASHRAE 62-89 standards (Ventilation for Acceptable Indoor Air Quality).
    • Condensate Drain - The 3/4 inch NPTF connection is rigidly mounted to assure proper fit and leak tight seal.
    • Durable Finish - The cabinet is made of pre-painted steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted-textured finish insure less fading when exposed to sunlight.
    • Full Perimeter Base Rails - The easily removable base rails provide a solid foundation for the entire unit and protects the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. On applications where the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the inch high base rails may be removed on location.
    • More Attractive Appearance - A single piece Water Shed top cover containing a top discharge condenser fan arrangement requires less square footage on installation and provides a wider variety of installations. The one piece design adds greater water integrity.
    • Top Discharge - The top discharge condenser fan does not disrupt neighboring areas or dry-out vegetation surrounding the unit. The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications.
    • Condenser Coil Grille - All DNZ024 thru 060 and DNQ060 models utilize a decorative "Wire Form" coil guard to provide impact protection against large objects. DNQ024 thru 04, and DNX024 thru 048 models utilize a stamped "Louvered" design which provides superior impact protection against smaller objects during transit and after installation.
    • Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound alterations with it's Super-Structure design. This design strategically places embossments in the pan for optimum strength and rigidity.
    • Fan System - All models operate over a wide range of design conditions with an electrically commutated fan motor. These units easily match all types of applications and provide greater on site flexibility to match comfort requirement. The cooling speed is factory set and can be field adjusted to a second speed. The heating speed is factory set to maintain mid point rise at the units heating input, but can be field adjusted. This allows maximum comfort conditions.
    • Simple Control Circuit - A low voltage printed circuit board contains a diagnostic indicator light and a low voltage terminal strip. An additional set of pin connectors is also provided to simplify the field interface of external controls. Mate-n-lock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted on a Control-Tilt control panel to allow the access cover to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded.
    • Protected Compressor - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur.
    • Pressure Switches - High pressure and low pressure/loss of charge switches standard in all units. When abnormal conditions are sensed through the pressure switches, the unit will lock out preventing any further operation until reset or problem is corrected.
    • Exclusive Coil Design - Grooved copper tubes and enhanced aluminum fin construction improves heat
    transfer for maximum efficiency and durability or MicroChannel aluminum tube, aluminum fin for long lasting durability and efficient operation.
    • Heat Exchangers - Are corrosion-resistant, aluminizedsteel tubular construction to provide long-life, trouble-free operation. The unique blow-through design also assures that condensate does not collect in humid areas when in the cooling cycle. This adds to longer heat exchanger life and higher long term Efficiencies.
    • Post Purge Induced Draft Combustion – Exhausts combustion products from the heat exchanger upon
    completion of the heating cycle to prolong the heat exchanger life.
    • Self Diagnostic Fan Control Module - Due to this self diagnostic control, less on site time is required to trouble shoot these units.
    • Spark To Pilot Ignition - Provides faster heat delivery. This ignition is highly reliable, durable and eliminates nuisance lockouts.
    • Multi Port In-shot Burners - No field adjustment is required to mix the air and gas. These burners are
    constructed of high-grade corrosion-resistant, aluminizedsteel.
    • Low Maintenance - Long life, permanently lubricated condenser and evaporator fan motor bearings need no annual maintenance adding greater reliability to the unit. Blower assembly can be easily cleaned by the unique Slip- Track slide-out blower assembly.
    • Secured Service Access Ports - Protected, externally mounted, re-usable service access ports are provided on both the high and low lines for ease of evacuating and charging the system. No final field mounting required.
    • Easy Service Access - A large, single panel covers the electrical and gas controls makes servicing easy. The blower compartment has an additional large panel with a built-in handle tab. Removing this panel will allow the blower assembly to slide-out for easy removal for maintenance and ease of trouble  shooting.
    • Replacement Parts - The installer requires no special training to replace any of the components of these units and does not need to maintain an inventory of unique parts.
    • System Integration - Each unit has the internal ability to integrate an electronic air cleaner or humidifier to work in conjunction with the base unit.
    Purchases made from Arkansas, Tennessee and Missouri must pay sales tax.  (eBay May require sale's tax from additional locations)
    (SS)
    Shipping Policy
    Your order will ship in 1-3 business days once payment has been received.  We process and ship orders Monday - Friday and do not ship on weekends or holidays.   Part's and such will be delivered via FedEx/UPS Ground or USPS Priority Mail and should be received in 1-5 business days from shipping date.
    Any equipment listing that offer Free shipping listing that requires shipping via any freight shipping company is only free to a BUSINESS ADDRESS WITH THE MEANS TO UNLOAD IT VIA A FORK LIFT.  FOR ANY RESIDENTIAL FREIGHT WITH A LIFT GATE, OR BUSINESS ADDRESS THAT REQUIRE A LIFT GATE FOR DELIVERIES THERE WILL BE ADDITIONAL CHARGES unless otherwise stated in the description for that listing.
    We ship via freight to the contiguous 48 states.  We will not be liable for undelivered orders due to the inaccessibility of the shipping address.  In that circumstance, we will work with you to arrange a nearby delivery or customer pick-up location.
    Do not sign for items that have NOT been inspected, once the Bill of Lading is signed, you will own it and remove most or all of the carrier's liability even if the signature is from someone else that received it on your behalf.  Inspect the shipment completely for any damages incurred during shipping.
    If the shipment is damaged,
    DO NOT SIGN FOR IT (IF YOU SIGN FOR IT YOU OWN IT AND THE SHIPPER IS NO LONGER LIABLE FOR THE DAMAGES
    ), contact the shipper immediately.  Concealed damages must be reported within 24 hours of receiving to the trucking company.  Truck drivers will try to rush you, take your time and make a complete inspection.  Take pictures if possible.
    We know times are tough and we ware willing to work with you.  We ask that if there is any problem you contact us and give us ample time to investigate and respond before you file a case.  Most problems can be worked out if we just communicate.
    Payment Policy/Refund Policy & Customer Service information
    Payments
    - Payments are expected within 3 business days.  Payments can be made through Paypal.  We report any nonpaying bidder to eBay.
    Returns
    -We hope you are pleased with your purchase.  All items are guaranteed to work and we will guarantee them for 30 days from the shipping date unless otherwise stated in the product description.  Warranties do not include freight charges.   At our discretion we will either refund or replace a warrantied item.  If an item arrives DOA, you have 14 days from the original purchase of your item to return it for a refund.  Buyers are responsible for all return shipping fees.  If a customer orders the wrong product, it is not returnable unless you contact us and then will be subject to a 10-20% restocking fee.  Please read description fully and check with what you need before purchasing any item.  Sales on electric items such as circuit boards are final and no returns will be honored.  All returns must be authorized.  You can call anytime and speak with Shawn Santini (870-307-0460) to obtain authorization.  Orders returned without authorization can lead to refunds being delayed and even denied.  We do not allow returns for any other reason.  We will inspect returned items before issuing a refund or replacing the warrantied item.  We have trained certified techs who will determine if returned items are defective.
    Customer Service
    - Please contact us with any questions/comments/complaints (870-307-0460).  We will make sure you are satisfied with your transaction!  Please give us a chance to resolve any issues before posting a feedback.  If your call is not answered, please leave a message and someone will return your call.  Our business hours are as followed:
    Monday-Friday: 8:00am - 5:00PM Central Standard Time\
    Saturday,Sunday and all major US Holidays: Closed
    Shop category
    Blower and Fan Motors
    Control Boards
    Compressors
    Contactors and Transformers
    Txv Valves
    Electrical Supplies
    HVAC Equipment
    Accepted Payments
    PayPal
    Payments are expected in 3 business days.  We report any nonpaying bidder to eBay.
    Shipping Services
    (What service is used depends on the size and weight of the item being shipped and is up to the discretion of Wade's unless otherwise stated by the buyer. )
    Contact Information
    Wade's Heating, Cooling & Electrical
    2850 Harrison St
    Batesville Ar, 72501
    (870) 307-0460
    Paypal Verified Seller